You are currently viewing our forum as a guest, which gives you limited access to view most discussions and access our other features. By joining our community, at no cost, you will have access to post topics, communicate privately with other members (PM), respond to polls, upload content and access many other special features. Registration is free, fast and simple, join the ThirdGen.org community today!
I have a single fan setup on a 91 TBI. I replaced the motor but the fan still doesn't come on at all. Is it the relay? If so, where is it located so I can troubleshoot?
Turn the key to the run position
unplug the fan switch pigtail from he head, between cylinders6 and 8. Ground the pin in the center of the plug to the block and see if the fan turns on.
If it does, the switch is bad, if it doesn't, the relay is possibly bad.
Fna relay in on the firewall by the brake booster.
I grounded the switch and it still doesn't kick on. I also tried reseting the ECM. I think the only thing left would be the relay, besides if it was the switch wouldn't it still work with the A/C on? It seems like the relay is what's common in both. I just don't know which relay it is. There are 3 that look the same. Two in the driver's side. One on the pass. side. Does anyone know which one it is?