Electronics Need help wiring something up? Thinking of adding an electrical component to your car? Need help troubleshooting that wiring glitch?

Heater/defrost/blower motor fan not working.

Old 10-10-2006, 09:15 PM
  #1  
Member

Thread Starter
iTrader: (1)
 
ling427ttvette's Avatar
 
Join Date: Dec 2005
Location: Dodge City, KS/Buffalo, OK
Posts: 385
Likes: 0
Received 0 Likes on 0 Posts
Car: 1983 Camaro Z28/1999 Cavalier
Engine: 305
Transmission: 700R4
Heater/defrost/blower motor fan not working.

Well, right before I bought my car the heater fan would not work on high. The previous owner fixed that, but it didn't last very long. It quit working on high after a while.

After a while longer, the fan just started randomly working. It would only work when the engine reached a certain RPM, usually around 3000RPM or so, and it would shut off once the RPM's dropped so low..

And now, it just does not work at all. I can turn it to heater, turn the heat up, turn the fan up, and all I get is a hissing noise... some kind of vacuum leak from behind the HVAC controls. When I was replacing my console I took a small look at the lines and stuff behind there and nothing, I un-plugged the main vacuum line and started my car, it has vacuum. There is no vacuum leak when all of the controls are off though.

I don't understand how a vacuum leak would cause the fan to not work though. What are some things I should look for?
Old 10-10-2006, 10:00 PM
  #2  
Member
 
19RS92's Avatar
 
Join Date: Aug 2006
Location: Brighton, Co
Posts: 137
Likes: 0
Received 0 Likes on 0 Posts
Car: 1992 RS 25th Anniversary
Engine: 305 TBI
Transmission: Auto
Axle/Gears: 3.42 posi
The vacuum only controls the ducting inside the dash (floor, defrost, vent). The blower motor is only controlled by electricity, the blower switch. If the fan only ran on low and medium, then randomly i would say the fan motor is bad. Turn the car on, turn the heater on with the blower switch in "high" position and test the motor using a simple test light. If there is no power to the motor the blower switch is probalby bad. If there is power to the motor and it does not run the motor is bad. Try tapping on the motor case and see if it starts to run, if it does replace it.
Old 10-11-2006, 06:16 PM
  #3  
Member

Thread Starter
iTrader: (1)
 
ling427ttvette's Avatar
 
Join Date: Dec 2005
Location: Dodge City, KS/Buffalo, OK
Posts: 385
Likes: 0
Received 0 Likes on 0 Posts
Car: 1983 Camaro Z28/1999 Cavalier
Engine: 305
Transmission: 700R4
Well, I went out and looked at it.

I checked the wires straight into the motor, it sporadically gets power, and the relay is clicking on and off. So, I went to O'reilly's and they had to freaking order the relay.

Anyways, this should solve the problem, if not this will be a start anyway.
Old 10-11-2006, 09:26 PM
  #4  
Member
 
bobdole369's Avatar
 
Join Date: Oct 2003
Location: South Florida (NW_Broward)
Posts: 405
Likes: 0
Received 0 Likes on 0 Posts
Car: 1989 Firebird
Engine: 2.8L V6 MPFI
Transmission: Beat to heck 700R4
If a relay is clicking theres a good chance it srill works. Redo the wires going TO that relay as they are the more likely cause. Also just fyi, on low and medium it goes through a load resistor. on high it simply puts all 12 volts into the fan. Not 100% on an 83 camaro, but on my 89 bird there is a connection near the firewall that went bad and got awfully corroded. This was the 12v line to the blower motor.
Old 10-12-2006, 12:16 AM
  #5  
Member
 
19RS92's Avatar
 
Join Date: Aug 2006
Location: Brighton, Co
Posts: 137
Likes: 0
Received 0 Likes on 0 Posts
Car: 1992 RS 25th Anniversary
Engine: 305 TBI
Transmission: Auto
Axle/Gears: 3.42 posi
If the relay is clicking it is doing its job. It gets its power from the fuse and the blower switch is what triggers it (makes it click). I still think you have a bad blower switch.
Old 10-12-2006, 01:32 PM
  #6  
Member

Thread Starter
iTrader: (1)
 
ling427ttvette's Avatar
 
Join Date: Dec 2005
Location: Dodge City, KS/Buffalo, OK
Posts: 385
Likes: 0
Received 0 Likes on 0 Posts
Car: 1983 Camaro Z28/1999 Cavalier
Engine: 305
Transmission: 700R4
Yeah, I almost think that the relay is still good.. because today and last night the fan was blowing.. I had it on high and it wasn't blowing that well, but it was blowing heat, thank god.

So, I will put a new relay in and I guess replace the switch as well. How do I do the switch, it's all tied in with the HVAC unit isn't it? Or does it come off seperately?
Old 10-12-2006, 03:20 PM
  #7  
Supreme Member

iTrader: (1)
 
sofakingdom's Avatar
 
Join Date: Sep 2005
Posts: 26,027
Received 1,662 Likes on 1,261 Posts
Car: Yes
Engine: Usually
Transmission: Sometimes
Axle/Gears: Behind me somewhere
https://www.thirdgen.org/forums/tech...no-longer.html
Old 10-12-2006, 04:13 PM
  #8  
Moderator

iTrader: (5)
 
JamesC's Avatar
 
Join Date: Aug 1999
Location: Lawrence, KS
Posts: 19,282
Received 93 Likes on 68 Posts
Car: Met. Silver 85 IROC/Sold
Engine: 350 HO Deluxe (350ci/330hp)
Transmission: T-5 (Non-WC)
Axle/Gears: Limited Slip 3.23's
Hey, Sofa,

Got that link bookmarked yet ? If not, you need to.

JamesC
Old 12-25-2010, 10:12 AM
  #9  
Junior Member
 
locutus918's Avatar
 
Join Date: Jan 2010
Location: Tulsa OK
Posts: 19
Likes: 0
Received 0 Likes on 0 Posts
Car: 89 formula firebird
Engine: formula 305 TPI
Transmission: 5 speed
Axle/Gears: 3.45
Re: Heater/defrost/blower motor fan not working.

if you take 12 volts and put directly to motor from battery this should test the motor correct?
Old 01-03-2011, 04:34 PM
  #10  
Junior Member
 
hitman0187's Avatar
 
Join Date: Dec 2003
Posts: 96
Likes: 0
Received 0 Likes on 0 Posts
Car: 87 Iroc 5.7 /86 Trans am
Engine: 5.7 TPI / 350 carb
Transmission: 700r4
Re: Heater/defrost/blower motor fan not working.

this thread is 4+ years old, but yes that should test the motor. Do you know where its located?
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
krisner89
Cooling
12
10-10-2015 06:03 AM
Ducati900ss
Camaros for Sale
1
09-02-2015 09:05 AM
thefirebirdm@n
Cooling
1
08-25-2015 05:21 PM
eightsixseven
Tech / General Engine
1
08-14-2015 03:09 PM
Leggman1
Transmissions and Drivetrain
3
08-06-2015 04:15 AM


Thread Tools
Search this Thread
Quick Reply: Heater/defrost/blower motor fan not working.



All times are GMT -5. The time now is 04:01 PM.