Heater/defrost/blower motor fan not working.
#1
Member
Thread Starter
iTrader: (1)
Join Date: Dec 2005
Location: Dodge City, KS/Buffalo, OK
Posts: 385
Likes: 0
Received 0 Likes
on
0 Posts
Car: 1983 Camaro Z28/1999 Cavalier
Engine: 305
Transmission: 700R4
Heater/defrost/blower motor fan not working.
Well, right before I bought my car the heater fan would not work on high. The previous owner fixed that, but it didn't last very long. It quit working on high after a while.
After a while longer, the fan just started randomly working. It would only work when the engine reached a certain RPM, usually around 3000RPM or so, and it would shut off once the RPM's dropped so low..
And now, it just does not work at all. I can turn it to heater, turn the heat up, turn the fan up, and all I get is a hissing noise... some kind of vacuum leak from behind the HVAC controls. When I was replacing my console I took a small look at the lines and stuff behind there and nothing, I un-plugged the main vacuum line and started my car, it has vacuum. There is no vacuum leak when all of the controls are off though.
I don't understand how a vacuum leak would cause the fan to not work though. What are some things I should look for?
After a while longer, the fan just started randomly working. It would only work when the engine reached a certain RPM, usually around 3000RPM or so, and it would shut off once the RPM's dropped so low..
And now, it just does not work at all. I can turn it to heater, turn the heat up, turn the fan up, and all I get is a hissing noise... some kind of vacuum leak from behind the HVAC controls. When I was replacing my console I took a small look at the lines and stuff behind there and nothing, I un-plugged the main vacuum line and started my car, it has vacuum. There is no vacuum leak when all of the controls are off though.
I don't understand how a vacuum leak would cause the fan to not work though. What are some things I should look for?
#2
Member
Join Date: Aug 2006
Location: Brighton, Co
Posts: 137
Likes: 0
Received 0 Likes
on
0 Posts
Car: 1992 RS 25th Anniversary
Engine: 305 TBI
Transmission: Auto
Axle/Gears: 3.42 posi
The vacuum only controls the ducting inside the dash (floor, defrost, vent). The blower motor is only controlled by electricity, the blower switch. If the fan only ran on low and medium, then randomly i would say the fan motor is bad. Turn the car on, turn the heater on with the blower switch in "high" position and test the motor using a simple test light. If there is no power to the motor the blower switch is probalby bad. If there is power to the motor and it does not run the motor is bad. Try tapping on the motor case and see if it starts to run, if it does replace it.
#3
Member
Thread Starter
iTrader: (1)
Join Date: Dec 2005
Location: Dodge City, KS/Buffalo, OK
Posts: 385
Likes: 0
Received 0 Likes
on
0 Posts
Car: 1983 Camaro Z28/1999 Cavalier
Engine: 305
Transmission: 700R4
Well, I went out and looked at it.
I checked the wires straight into the motor, it sporadically gets power, and the relay is clicking on and off. So, I went to O'reilly's and they had to freaking order the relay.
Anyways, this should solve the problem, if not this will be a start anyway.
I checked the wires straight into the motor, it sporadically gets power, and the relay is clicking on and off. So, I went to O'reilly's and they had to freaking order the relay.
Anyways, this should solve the problem, if not this will be a start anyway.
#4
Member
Join Date: Oct 2003
Location: South Florida (NW_Broward)
Posts: 405
Likes: 0
Received 0 Likes
on
0 Posts
Car: 1989 Firebird
Engine: 2.8L V6 MPFI
Transmission: Beat to heck 700R4
If a relay is clicking theres a good chance it srill works. Redo the wires going TO that relay as they are the more likely cause. Also just fyi, on low and medium it goes through a load resistor. on high it simply puts all 12 volts into the fan. Not 100% on an 83 camaro, but on my 89 bird there is a connection near the firewall that went bad and got awfully corroded. This was the 12v line to the blower motor.
#5
Member
Join Date: Aug 2006
Location: Brighton, Co
Posts: 137
Likes: 0
Received 0 Likes
on
0 Posts
Car: 1992 RS 25th Anniversary
Engine: 305 TBI
Transmission: Auto
Axle/Gears: 3.42 posi
If the relay is clicking it is doing its job. It gets its power from the fuse and the blower switch is what triggers it (makes it click). I still think you have a bad blower switch.
#6
Member
Thread Starter
iTrader: (1)
Join Date: Dec 2005
Location: Dodge City, KS/Buffalo, OK
Posts: 385
Likes: 0
Received 0 Likes
on
0 Posts
Car: 1983 Camaro Z28/1999 Cavalier
Engine: 305
Transmission: 700R4
Yeah, I almost think that the relay is still good.. because today and last night the fan was blowing.. I had it on high and it wasn't blowing that well, but it was blowing heat, thank god.
So, I will put a new relay in and I guess replace the switch as well. How do I do the switch, it's all tied in with the HVAC unit isn't it? Or does it come off seperately?
So, I will put a new relay in and I guess replace the switch as well. How do I do the switch, it's all tied in with the HVAC unit isn't it? Or does it come off seperately?
#7
Supreme Member
iTrader: (1)
Join Date: Sep 2005
Posts: 26,050
Received 1,672 Likes
on
1,269 Posts
Car: Yes
Engine: Usually
Transmission: Sometimes
Axle/Gears: Behind me somewhere
Trending Topics
#9
Junior Member
Join Date: Jan 2010
Location: Tulsa OK
Posts: 19
Likes: 0
Received 0 Likes
on
0 Posts
Car: 89 formula firebird
Engine: formula 305 TPI
Transmission: 5 speed
Axle/Gears: 3.45
Re: Heater/defrost/blower motor fan not working.
if you take 12 volts and put directly to motor from battery this should test the motor correct?
#10
Junior Member
Join Date: Dec 2003
Posts: 96
Likes: 0
Received 0 Likes
on
0 Posts
Car: 87 Iroc 5.7 /86 Trans am
Engine: 5.7 TPI / 350 carb
Transmission: 700r4
Re: Heater/defrost/blower motor fan not working.
this thread is 4+ years old, but yes that should test the motor. Do you know where its located?