BR,
The ALDL jumper procedure is used on older ECMs and some V-6 and I-4 engines to set base timing. Your TPI uses a bypass connector in the EST system to set base timing. There should be a VECI label under the hood describing the adjustment procedure, and it should look like this:
The bypass connector should be disconnected and the base timing set to the specification. Reconnect the bypass connector and you're set. The connector should be found here:
------------------
Later,
Vader
------------------
"
No matter how hard you try you can't stop us now"