fans run manually not automatically

I have a 1988 Iroc 5.7 with dual cooling fans.I have both green/white wires rigged up to separate toggle switches to turn on one fan or both fans.Why do the fans not come on automatically?I have replaced the fan switch for the secondary fan twice and still nothing and checked the green/white wire for the primary fan back to the ECM terminal C1 and it is good.It seems like neither fan is receiving a signal to trigger it.What could cause this?Is it possible the temp guage is that far off even when it is in the red the engine is still not hot enough to trigger the fans?Thanks for any replies.

Last edited by m smith; 06-03-2012 at 05:44 PM.
Old 06-04-2012, 03:51 PM
  #2  
Supreme Member

 
NINÅ's Avatar
 
Join Date: Jan 2006
Location: Mooresville NC
Posts: 3,341
Likes: 0
Received 10 Likes on 10 Posts
Car: LOWERED ♦ CRIMSON METALFLAKE
Engine: ► 400 KUBES ◄
Transmission: 765R4
Axle/Gears: EATON POSI 4.56
Fan Plan

With the key in the RUN position, ground the wire going to the Fan Switch in the engine.

What happens?


Happy Racing!



Make Noise, Turn Left, Repeat

.

Old 06-04-2012, 05:12 PM
  #3  
Junior Member

Thread Starter
 
m smith's Avatar
 
Join Date: Mar 2010
Posts: 40
Likes: 0
Received 0 Likes on 0 Posts
Re: Fan Plan

Secondary fan turns on.The switch has been changed 3 times and still nothing.Maybe the cheap connecter that keeps on melting loses contact with the switch.
Old 06-05-2012, 08:30 PM
  #4  
Supreme Member

iTrader: (15)
 
Tibo's Avatar
 
Join Date: Jun 2003
Location: Desert
Posts: 5,025
Received 76 Likes on 66 Posts
Car: 1991 Z28 Vert
Engine: 383 single plane efi
Transmission: T-56
Axle/Gears: 8.8 with 3.73s
Re: fans run manually not automatically

If you are using the green/white wire make certain the switch is not inline with the green/white wire, if it is then that is your problem. The green/white wire is trigger wire for the relay and only needs a few amps at most. You want to splice in or solder into the green/white wire another wire, two wires going into one. I believe that the ecm grounds out the relay with the green/white wire, so you would want that wire to be a switchable ground.
Look at this page:
http://www.bcae1.com/relays.htm
Old 06-05-2012, 09:33 PM
  #5  
Junior Member

Thread Starter
 
m smith's Avatar
 
Join Date: Mar 2010
Posts: 40
Likes: 0
Received 0 Likes on 0 Posts
Re: fans run manually not automatically

All original wiring intact.All I did was splice a single wire from the green/white wire on the primary relay to a switch inside the car and a wire from the switch to ground.Did the same for secondary relay.This way I can turn on primary fan or secondary fan or both at the same time.Relays ,fuses and wiring unchanged and non powered switches.Also this way there is no power to the fans with key off so if you forget to turn them off it won`t matter because when you turn the ignition off the fans will shut off and not drain the battery.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
jhawkeye
Engine Swap
5
05-25-2022 06:33 PM
RazorN8
Tech / General Engine
4
01-07-2022 11:44 AM
kyleb24
Camaros for Sale
2
08-15-2015 08:24 AM
eightsixseven
Tech / General Engine
1
08-14-2015 03:09 PM
1992 Trans Am
Engine/Drivetrain/Suspension Parts for Sale
1
08-08-2015 08:16 PM



Quick Reply: fans run manually not automatically



All times are GMT -5. The time now is 10:59 AM.