Cooling Discuss all of the aspects of cooling that you can think of! Radiators, transmissions, electric fans, etc.

Single Electric Fan Runs constant.

Thread Tools
 
Search this Thread
 
Old 04-30-2011, 07:50 PM
  #1  
Senior Member

Thread Starter
iTrader: (4)
 
onthedownlow's Avatar
 
Join Date: Apr 2009
Location: Ontario
Posts: 617
Likes: 0
Received 0 Likes on 0 Posts
Car: 1984 Camaro Berlinetta
Engine: 355
Transmission: T5
Axle/Gears: Australian 9 bolt 3.27 posi
Single Electric Fan Runs constant.

Hello all, so here is my question. I have a single electric fan set up in my 84 camaro. I had to buy an aftermarket fan controller so I purchased a Derale fan controller and it has worked very well so far. At this point I have the fan controller set to have the fan come on when the temperature hits 160. The temperature has never gone beyond 180 but the fan never shuts off....once the engine is warmed up the fan stays on until you shut the ignition off. Should I have the fan set to come on before 160? Also wondering is it normal for the single fan to be going all the time?? I have been thinking about switching to a dual fan set up for awhile, but I am definitely looking for some guidance. Does the dual fan set up run non stop too?? or does it cool the engine enough that the fans shut off periodically??

onthedownlow
Old 05-01-2011, 01:21 PM
  #2  
TGO Supporter

 
deadbird's Avatar
 
Join Date: Sep 2000
Location: So.west IN
Posts: 6,775
Likes: 0
Received 26 Likes on 23 Posts
Car: 87 Formula/ 00 Xtreme
Engine: TPI 305/ v6
Transmission: struggling t-5/ 4l60E
Axle/Gears: 3.08/ 3.23
Re: Single Electric Fan Runs constant.

It is normal for a factory fan to come on at a much higher temperature. A ECM controlled fan will turn on at 220*F. A fan switch controlled fan turns on at 238*°F.

Having the fan turn on before the thermostat is even open is usless.
Having it set below the thermostat temperature will obviously make the fan run constant as the controller can never reach its turn off temperature (usually a 10-15° lower turn-off temp then what turn-on is set for).
If you have a 160° thermostat, and the fan controller is set to 160°, the controller can never get the coolant temp down to the point it will shut the fan off.
Old 05-01-2011, 04:43 PM
  #3  
Senior Member

Thread Starter
iTrader: (4)
 
onthedownlow's Avatar
 
Join Date: Apr 2009
Location: Ontario
Posts: 617
Likes: 0
Received 0 Likes on 0 Posts
Car: 1984 Camaro Berlinetta
Engine: 355
Transmission: T5
Axle/Gears: Australian 9 bolt 3.27 posi
Re: Single Electric Fan Runs constant.

Deadbird,


Thanks for your help. I am pretty sure the thermostat I have in there is a 180 degree. So would it be a better idea to adjust the fan controller so the fan comes on when the engine temp hits 180-185? Does anyone out there who is running a single fan set up have the same issue? or am I the only one with a single fan that wont shut off?
Old 05-01-2011, 06:32 PM
  #4  
Supreme Member

 
camaronewbie's Avatar
 
Join Date: Sep 2002
Location: Cary, North Carolina
Posts: 9,192
Likes: 0
Received 16 Likes on 16 Posts
Car: 1992 RS
Engine: Carbed 350
Transmission: 700R4
Axle/Gears: 3.42 posi
Re: Single Electric Fan Runs constant.

I'm running a 180 stat, I have fan set to come on at about 195.
Old 05-01-2011, 06:38 PM
  #5  
TGO Supporter

 
deadbird's Avatar
 
Join Date: Sep 2000
Location: So.west IN
Posts: 6,775
Likes: 0
Received 26 Likes on 23 Posts
Car: 87 Formula/ 00 Xtreme
Engine: TPI 305/ v6
Transmission: struggling t-5/ 4l60E
Axle/Gears: 3.08/ 3.23
Re: Single Electric Fan Runs constant.

If you want the fan to cycle, you should set it at a minimum of +15° above the thermostat opening temperature.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
RazorN8
Tech / General Engine
4
01-07-2022 11:44 AM
Ikes 91Z
LTX and LSX
21
12-09-2015 03:49 PM
86IROC112
Engine/Drivetrain/Suspension Parts for Sale
4
08-17-2015 02:00 PM
eightsixseven
Tech / General Engine
1
08-14-2015 03:09 PM



Quick Reply: Single Electric Fan Runs constant.



All times are GMT -5. The time now is 01:01 PM.