Crossfire Injection Issues
#53
Re: Crossfire Injection Issues
I'm hating this cfi right now...bought a new ECM, plugged it in and jack squat. Same bull as before. I'm positive the ECM has power and ground...
#55
Re: Crossfire Injection Issues
Was looking in the service manual and they are for sure supposed to go on when the key is in the second position, and I have a 84 Corvette and the ecm fits like I believe it should. According to the service manual, I either have a faulty ecm or connector, but neither of which seem like the problem as how does a connector go bad and the ecm is brand new. Also, I checked the 450 and 450r grounds in the backpins of the connector, is that alright? Here's the flow chart.
#57
Member
Join Date: Mar 2009
Location: HONOLULU HI
Posts: 209
Likes: 0
Received 0 Likes
on
0 Posts
Car: 83 Z28 Crossfire
Engine: 305
Transmission: 700R4
Axle/Gears: 3.23
#58
Re: Crossfire Injection Issues
It appears like none of the lights are getting power except the security light. When I put 12v to the circuit a relay clicks in the engine bay and the lights all turn on but it still does not start...interesting.
#59
Member
Join Date: Mar 2009
Location: HONOLULU HI
Posts: 209
Likes: 0
Received 0 Likes
on
0 Posts
Car: 83 Z28 Crossfire
Engine: 305
Transmission: 700R4
Axle/Gears: 3.23
#60
Member
Join Date: Mar 2009
Location: HONOLULU HI
Posts: 209
Likes: 0
Received 0 Likes
on
0 Posts
Car: 83 Z28 Crossfire
Engine: 305
Transmission: 700R4
Axle/Gears: 3.23
Re: Crossfire Injection Issues
What relay is that? Maybe a problem with the anti theft system?
#61
Re: Crossfire Injection Issues
The anti theft system clicks when it's activated though, on my car at least. The relay is underneath the front left headlight right by the carbon canister.
#63
Member
Join Date: Mar 2009
Location: HONOLULU HI
Posts: 209
Likes: 0
Received 0 Likes
on
0 Posts
Car: 83 Z28 Crossfire
Engine: 305
Transmission: 700R4
Axle/Gears: 3.23
Re: Crossfire Injection Issues
Looked at my Camaro wiring diagram the 10 amp gauges fuse in fuse box feeds the purge solenoid. When I pull the fuse it kills my check engine light also. Either that fuse is blown or your feed from the ignition switch is no good. One other thing I recommend when chasing any electrical gremlins is to check ALL THE FUSES for blown/missing no matter how it's labeled in the fuse box.
#64
Re: Crossfire Injection Issues
It was the magnetic pickup coil in the distributor that was the problem, and somehow the check engine light came back on as well. However, when I start my car if it doesn't 'catch' by the 2nd or 3rd turn over it floods the manifold. It seems as if it could be just the driver side injector, or maybe that side of the manifold is just the lowest point, either way there is 3/16" worth of fuel sitting there.
#65
Supreme Member
iTrader: (4)
Re: Crossfire Injection Issues
Sure - the pickup would leave you without a reference for the injectors. I wish I had mentioned that to you in the beginning. I swapped mine out when I did the ICM to eliminate it as a cause.
As far as the hard starting issue, did you set the timing? It should be set with the EST bypass disconnected to 6 degrees. BTDC.
As far as the hard starting issue, did you set the timing? It should be set with the EST bypass disconnected to 6 degrees. BTDC.
#66
Re: Crossfire Injection Issues
Sure - the pickup would leave you without a reference for the injectors. I wish I had mentioned that to you in the beginning. I swapped mine out when I did the ICM to eliminate it as a cause.
As far as the hard starting issue, did you set the timing? It should be set with the EST bypass disconnected to 6 degrees. BTDC.
As far as the hard starting issue, did you set the timing? It should be set with the EST bypass disconnected to 6 degrees. BTDC.
#67
Member
Join Date: Mar 2009
Location: HONOLULU HI
Posts: 209
Likes: 0
Received 0 Likes
on
0 Posts
Car: 83 Z28 Crossfire
Engine: 305
Transmission: 700R4
Axle/Gears: 3.23
Re: Crossfire Injection Issues
It was the magnetic pickup coil in the distributor that was the problem, and somehow the check engine light came back on as well. However, when I start my car if it doesn't 'catch' by the 2nd or 3rd turn over it floods the manifold. It seems as if it could be just the driver side injector, or maybe that side of the manifold is just the lowest point, either way there is 3/16" worth of fuel sitting there.
#68
Re: Crossfire Injection Issues
I don't think it was the magnetic coil that fixed the light, I think foraging around the wiring near the radio fixed some sketchy connection back there, but i'm not positive. I aired out the manifold and today the engine started fine without incident. Only thing is, battery isn't charging. I put a 50ohm resistor inline to the exciter wire to the alternator branched off of the radio switched power input.