Test the Hall Effect in Distributor
Hi All,
How do I test if the Magnetic Hall effect sensor in the distributor is working?
(Magnetic Reluctor) It's the 8 pointed star that sits on top of the Pick up coil.
I have a 1989 Iroc 5.0 conv. auto
Original 28k miles
Was driving fine then simply turned off. It cranks, turns over, but won't start.
Has 46psi fuel pressure to the rail, good spark at the plugs, No security light.
It will run for a few seconds if I spray starting fluid.
So, I don't think it's fuel related or ignition related or VATS related.
It seems like the ECM is not telling the injectors to fire just like this thread.
https://www.thirdgen.org/forums/tech...art-story.html
So before I buy a new distributor, I'd like to diagnose if it's the magnetic sensor.
Anybody ever tested that sensor?
How do I test if the Magnetic Hall effect sensor in the distributor is working?
(Magnetic Reluctor) It's the 8 pointed star that sits on top of the Pick up coil.
I have a 1989 Iroc 5.0 conv. auto
Original 28k miles
Was driving fine then simply turned off. It cranks, turns over, but won't start.
Has 46psi fuel pressure to the rail, good spark at the plugs, No security light.
It will run for a few seconds if I spray starting fluid.
So, I don't think it's fuel related or ignition related or VATS related.
It seems like the ECM is not telling the injectors to fire just like this thread.
https://www.thirdgen.org/forums/tech...art-story.html
So before I buy a new distributor, I'd like to diagnose if it's the magnetic sensor.
Anybody ever tested that sensor?
#2
Supreme Member
iTrader: (1)
Join Date: Sep 2005
Posts: 26,141
Received 1,692 Likes
on
1,286 Posts
Car: Yes
Engine: Usually
Transmission: Sometimes
Axle/Gears: Behind me somewhere
Re: Test the Hall Effect in Distributor
If it runs, ever, at all, then the problem isn't the pickup coil.
If it runs with starting fluid, it's a fuel problem. Check inj 1 & inj 2 fuses.
If it runs with starting fluid, it's a fuel problem. Check inj 1 & inj 2 fuses.
#3
Junior Member
Thread Starter
Join Date: Jul 2007
Location: Perry Ga
Posts: 10
Likes: 0
Received 0 Likes
on
0 Posts
Car: 1989 IROC-Z conv
Engine: 305
Transmission: Auto
Re: Test the Hall Effect in Distributor
Yes, the coil checks out good. has 800 ohms.
I'm trying to test the reluctor that sits on top of the coil.
the magnetic reluctor sends a signal to the ECM.
just don't know how to test it.
I'm trying to test the reluctor that sits on top of the coil.
the magnetic reluctor sends a signal to the ECM.
just don't know how to test it.
#5
Supreme Member
iTrader: (1)
Join Date: Sep 2005
Posts: 26,141
Received 1,692 Likes
on
1,286 Posts
Car: Yes
Engine: Usually
Transmission: Sometimes
Axle/Gears: Behind me somewhere
Re: Test the Hall Effect in Distributor
If the car runs when you shoot starting fluid in it, that part isn't bad.
You don't need to test it. You already did, with starting fluid.
You have a fuel problem, not a distributor problem.
You don't need to test it. You already did, with starting fluid.
You have a fuel problem, not a distributor problem.
#6
Junior Member
Thread Starter
Join Date: Jul 2007
Location: Perry Ga
Posts: 10
Likes: 0
Received 0 Likes
on
0 Posts
Car: 1989 IROC-Z conv
Engine: 305
Transmission: Auto
Re: Test the Hall Effect in Distributor
Yes, I understand what you're saying and I agree that it's a fuel problem. My point is that this sensor sends a signal to the ECM for the crank position and the ECM allows the fuel injectors to cycle at the proper time. so, if this sensor is bad, then the ECU won't send the signal for the injectors to open.
Trending Topics
#8
Supreme Member
iTrader: (1)
Join Date: Sep 2005
Posts: 26,141
Received 1,692 Likes
on
1,286 Posts
Car: Yes
Engine: Usually
Transmission: Sometimes
Axle/Gears: Behind me somewhere
Re: Test the Hall Effect in Distributor
What Drew said.
If the dist makes sparks, the pickup is working.
You have a fuel problem, not a dist problem. Probably also not an ECM problem. More likely, something simple.
If the dist makes sparks, the pickup is working.
You have a fuel problem, not a dist problem. Probably also not an ECM problem. More likely, something simple.
#9
Supreme Member
iTrader: (1)
Join Date: Feb 2017
Location: Meriden, CT 06450
Posts: 4,034
Received 517 Likes
on
431 Posts
Car: 84 TA orig. 305 LG4 "H" E4ME
Engine: 334 SBC - stroked 305 M4ME Q-Jet
Transmission: upgraded 700R4 3200 stall
Axle/Gears: 10bolt 4.10 Posi w Lakewood TA Bars
Re: Test the Hall Effect in Distributor
To answer your question, you need an oscilloscope to test that coil.
Without one, you can only make resistance checks with an ohmmeter.
And if it has an intermittent problem that only shows up when it gets hot,
then a bench test will not reveal that.
Without one, you can only make resistance checks with an ohmmeter.
And if it has an intermittent problem that only shows up when it gets hot,
then a bench test will not reveal that.
#12
Member
iTrader: (1)
Join Date: Dec 2001
Location: Finland
Posts: 456
Likes: 0
Received 2 Likes
on
2 Posts
Car: 1985 Camaro Z-28
Engine: 385
Transmission: th700r4+Edge 2800 stall
Axle/Gears: 3.42
Re: Test the Hall Effect in Distributor
You can measure ac volts(~2...3VAC) from pick up coil wires when you crank engine with starter.
#13
Supreme Member
iTrader: (1)
Join Date: Sep 2005
Posts: 26,141
Received 1,692 Likes
on
1,286 Posts
Car: Yes
Engine: Usually
Transmission: Sometimes
Axle/Gears: Behind me somewhere
Re: Test the Hall Effect in Distributor
You can test it even more easily by shooting starting fluid into the intake.
If the engine runs, the pickup is good.
Oh wait... already been there and done that.
Time to move on. Leave the dist alone and find the trouble in the fuel system.
If the engine runs, the pickup is good.
Oh wait... already been there and done that.
Time to move on. Leave the dist alone and find the trouble in the fuel system.
#14
Moderator
iTrader: (1)
Join Date: Mar 2002
Location: Chasing Electrons
Posts: 18,406
Likes: 0
Received 217 Likes
on
203 Posts
Car: check
Engine: check
Transmission: check
Re: Test the Hall Effect in Distributor
It can still be the ICM in the distributor. The ECM requires reference pulses from it to fire the injectors.
RBob.