Test the Hall Effect in Distributor

Hi All,
How do I test if the Magnetic Hall effect sensor in the distributor is working?
(Magnetic Reluctor) It's the 8 pointed star that sits on top of the Pick up coil.

I have a 1989 Iroc 5.0 conv. auto
Original 28k miles
Was driving fine then simply turned off. It cranks, turns over, but won't start.
Has 46psi fuel pressure to the rail, good spark at the plugs, No security light.
It will run for a few seconds if I spray starting fluid.
So, I don't think it's fuel related or ignition related or VATS related.
It seems like the ECM is not telling the injectors to fire just like this thread.
https://www.thirdgen.org/forums/tech...art-story.html

So before I buy a new distributor, I'd like to diagnose if it's the magnetic sensor.
Anybody ever tested that sensor?
Old 05-19-2018, 02:49 PM
  #2  
Supreme Member

iTrader: (1)
 
sofakingdom's Avatar
 
Join Date: Sep 2005
Posts: 26,141
Received 1,692 Likes on 1,286 Posts
Car: Yes
Engine: Usually
Transmission: Sometimes
Axle/Gears: Behind me somewhere
Re: Test the Hall Effect in Distributor

If it runs, ever, at all, then the problem isn't the pickup coil.

If it runs with starting fluid, it's a fuel problem. Check inj 1 & inj 2 fuses.
Old 05-19-2018, 02:55 PM
  #3  
Junior Member
Thread Starter
 
bigbear807's Avatar
 
Join Date: Jul 2007
Location: Perry Ga
Posts: 10
Likes: 0
Received 0 Likes on 0 Posts
Car: 1989 IROC-Z conv
Engine: 305
Transmission: Auto
Re: Test the Hall Effect in Distributor

Yes, the coil checks out good. has 800 ohms.
I'm trying to test the reluctor that sits on top of the coil.
the magnetic reluctor sends a signal to the ECM.
just don't know how to test it.
Old 05-19-2018, 03:05 PM
  #4  
Junior Member
Thread Starter
 
bigbear807's Avatar
 
Join Date: Jul 2007
Location: Perry Ga
Posts: 10
Likes: 0
Received 0 Likes on 0 Posts
Car: 1989 IROC-Z conv
Engine: 305
Transmission: Auto
Re: Test the Hall Effect in Distributor

This is what I'm trying to test to see if it's bad.
Old 05-19-2018, 04:01 PM
  #5  
Supreme Member

iTrader: (1)
 
sofakingdom's Avatar
 
Join Date: Sep 2005
Posts: 26,141
Received 1,692 Likes on 1,286 Posts
Car: Yes
Engine: Usually
Transmission: Sometimes
Axle/Gears: Behind me somewhere
Re: Test the Hall Effect in Distributor

If the car runs when you shoot starting fluid in it, that part isn't bad.

You don't need to test it. You already did, with starting fluid.

You have a fuel problem, not a distributor problem.
Old 05-19-2018, 04:20 PM
  #6  
Junior Member
Thread Starter
 
bigbear807's Avatar
 
Join Date: Jul 2007
Location: Perry Ga
Posts: 10
Likes: 0
Received 0 Likes on 0 Posts
Car: 1989 IROC-Z conv
Engine: 305
Transmission: Auto
Re: Test the Hall Effect in Distributor

Yes, I understand what you're saying and I agree that it's a fuel problem. My point is that this sensor sends a signal to the ECM for the crank position and the ECM allows the fuel injectors to cycle at the proper time. so, if this sensor is bad, then the ECU won't send the signal for the injectors to open.
Old 05-19-2018, 06:30 PM
  #7  
Supreme Member

iTrader: (58)
 
Drew's Avatar
 
Join Date: Jul 1999
Location: Salina, KS
Posts: 20,309
Received 1,052 Likes on 748 Posts
Re: Test the Hall Effect in Distributor

LOL It also sends a signal to the ignition to spark the plugs. You have spark, the pickup is fine.
Old 05-19-2018, 07:31 PM
  #8  
Supreme Member

iTrader: (1)
 
sofakingdom's Avatar
 
Join Date: Sep 2005
Posts: 26,141
Received 1,692 Likes on 1,286 Posts
Car: Yes
Engine: Usually
Transmission: Sometimes
Axle/Gears: Behind me somewhere
Re: Test the Hall Effect in Distributor

What Drew said.

If the dist makes sparks, the pickup is working.

You have a fuel problem, not a dist problem. Probably also not an ECM problem. More likely, something simple.
Old 05-19-2018, 08:46 PM
  #9  
Supreme Member
iTrader: (1)
 
NoEmissions84TA's Avatar
 
Join Date: Feb 2017
Location: Meriden, CT 06450
Posts: 4,034
Received 517 Likes on 431 Posts
Car: 84 TA orig. 305 LG4 "H" E4ME
Engine: 334 SBC - stroked 305 M4ME Q-Jet
Transmission: upgraded 700R4 3200 stall
Axle/Gears: 10bolt 4.10 Posi w Lakewood TA Bars
Re: Test the Hall Effect in Distributor

To answer your question, you need an oscilloscope to test that coil.
Without one, you can only make resistance checks with an ohmmeter.
And if it has an intermittent problem that only shows up when it gets hot,
then a bench test will not reveal that.
Old 05-19-2018, 09:14 PM
  #10  
Junior Member
Thread Starter
 
bigbear807's Avatar
 
Join Date: Jul 2007
Location: Perry Ga
Posts: 10
Likes: 0
Received 0 Likes on 0 Posts
Car: 1989 IROC-Z conv
Engine: 305
Transmission: Auto
Re: Test the Hall Effect in Distributor

thanks for all the help guys.
I appreciate it.
Old 05-20-2018, 06:43 PM
  #11  
Moderator

iTrader: (3)
 
Abubaca's Avatar
 
Join Date: Feb 2001
Location: JAMESTOWN, NC
Posts: 8,369
Received 348 Likes on 275 Posts
Car: 1988 Iroc
Engine: L98 350
Transmission: 700R4
Axle/Gears: Hawks 8.8 - 3.73
Re: Test the Hall Effect in Distributor

Pretty sure it's a Variable Reluctance sensor, not a Hall effect.

....but it looks like we're past that.
Old 05-21-2018, 03:35 AM
  #12  
Member

iTrader: (1)
 
z 28 jari's Avatar
 
Join Date: Dec 2001
Location: Finland
Posts: 456
Likes: 0
Received 2 Likes on 2 Posts
Car: 1985 Camaro Z-28
Engine: 385
Transmission: th700r4+Edge 2800 stall
Axle/Gears: 3.42
Re: Test the Hall Effect in Distributor

You can measure ac volts(~2...3VAC) from pick up coil wires when you crank engine with starter.
Old 05-21-2018, 07:43 AM
  #13  
Supreme Member

iTrader: (1)
 
sofakingdom's Avatar
 
Join Date: Sep 2005
Posts: 26,141
Received 1,692 Likes on 1,286 Posts
Car: Yes
Engine: Usually
Transmission: Sometimes
Axle/Gears: Behind me somewhere
Re: Test the Hall Effect in Distributor

You can test it even more easily by shooting starting fluid into the intake.

If the engine runs, the pickup is good.

Oh wait... already been there and done that.

Time to move on. Leave the dist alone and find the trouble in the fuel system.
Old 05-22-2018, 07:31 AM
  #14  
Moderator

iTrader: (1)
 
RBob's Avatar
 
Join Date: Mar 2002
Location: Chasing Electrons
Posts: 18,406
Likes: 0
Received 217 Likes on 203 Posts
Car: check
Engine: check
Transmission: check
Re: Test the Hall Effect in Distributor

It can still be the ICM in the distributor. The ECM requires reference pulses from it to fire the injectors.

RBob.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Gray Ghost 8991
Electronics
7
09-23-2017 07:01 AM
smokefan
DIY PROM
2
03-20-2006 05:24 PM
Baron
Tech / General Engine
3
01-02-2001 12:18 PM



Quick Reply: Test the Hall Effect in Distributor



All times are GMT -5. The time now is 11:54 PM.